The future of fuelling, for Australian mines, farms, ports and commercial fleets, is not a yard that has given up diesel. The engines already in the field still do the heavy work, and a plan that pretends otherwise leaves a tank empty. What is changing is the record around the load: who can see the product, who can release a truck, and who can show, months later, that a stated number of litres went into a stated tank at a stated temperature.
That record used to live in a dip book, a driver's folder and an accounts inbox that never met. A site could be short of fuel and long on paper, or the reverse, and the argument started only when an engine stopped or an invoice looked wrong. Tank telemetry, dispatch software, temperature-corrected meters, electronic dockets, fuel cards and laboratory results earn their keep when they close that gap. They are decoration when they produce a screen nobody is allowed to act on. The molecule in commercial diesel has not been replaced. The paperwork around it has.
Bulk supply is still a physical sequence: a terminal lift, a heavy vehicle, a meter, and a tank the customer controls. The fuel supply job remains a driver, a hose, a window and a quantity both sides will accept.
The sites that feel the change first already had a person whose job was to know the tank. The new tools either give that person a better instrument or they bury the same job under alerts. This page is about that operating system, not about appointing a supplier. What a supplier is accountable for on the day of the drop is set out separately in the note on what a fuel supplier controls. So is how to choose a fuel supplier, and so is the narrower question of choosing a bulk supplier. Those are appointment decisions. The subject here is what happens to the litre once a supply arrangement is already in motion.
A tank gauge is a measuring instrument with a communications problem attached. Older sites still use a dipstick, a clock face, or a float and tape. Newer installations use a magnetostrictive probe, a pressure sensor, or a radar head. Each reports a level. Litres come later, from a calibration chart built for that shell. If the chart is wrong, the telemetry is precisely wrong, which is worse than a dipstick the operator does not fully trust.
The figure that should drive a reorder is usable diesel, not total liquid and not shell capacity. Free water sits under the product. Some probes sense that interface as well as the fuel level, and a rising water bottom can look like a gain if the reading is total liquid. A tank also has a heel. The last centimetres are not reliable supply, and a high fill has to leave room so a delivery does not wet the vent. Usable ullage is capacity, minus product, minus water, minus the margin the site means to keep. A single percentage that merely calls the tank full has thrown those distinctions away.
Temperature sits inside the same reading. A tank that gained litres over a hot afternoon may have gained heat, not a delivery. Store level, temperature and water, and convert with the chart for that vessel. A horizontal tank does not give the same litres per millimetre at mid-height as it does near the bottom.
Remote sites are where telemetry is most useful and where it fails in ordinary ways. Mobile coverage on a Wheatbelt farm, a pastoral lease or a construction pad is often one tower and a tank on the wrong side of a shed. A mine can have a private network in the pit and a dead spot at the fuel farm. Put the transmitter where the signal is. Where the mobile network does not reach, use satellite or radio. A quiet tank, or a solar unit that died overnight, must not be treated as a full tank. A stale reading has to block an automatic order.
Alerts are only as good as the person who can turn them into a load. A low alarm sent to a shared inbox, with nobody named as the one who orders, is a graph. The same is true of a high alarm that fires when the product is already at the vent. A standing onsite diesel delivery on a rhythm the tank can accept will prevent more stock-outs than a sensor that creates an urgent load every Friday. The probe should catch the week that breaks the rhythm. The physical drop is set out in the notes on onsite refuelling.
Reorder points copied from an average month are how harvests and shutdowns go wrong. A broadacre shed can burn several times its July rate in a seeding or harvest fortnight, and a mine drawing down for maintenance does not have one number that is also right for the restart. The setpoint has to change, and the change has to expire, or a harvest setting is still ordering full loads in March. Who may accept an alarm, who may override it, and who may place the order should sit with the phone numbers.
Ullage has to be checked against the inbound truck, not against a percentage. Do not load what the tank cannot hold, and do not leave a second order open for the same tank unless the ullage covers both.
A dispatch system is a list of constraints that happen to have a geography. The load has to exist at a terminal. The vehicle has to be legal for the road and for the site. The driver has to have hours left under the fatigue module they are actually running. The customer has to have ullage, a person who can receive, and an induction that has not expired. Cutting kilometres while ignoring any one of those leaves a truck parked at a grill. In Western Australia, fuel transportation time is a large share of the cost of a remote drop, and it is also a fatigue problem.
Western Australia sits outside the Heavy Vehicle National Law, so concessional access is a Western Australian Heavy Vehicle Accreditation question: fatigue, maintenance, and dimension and loading where the operator needs them. In states under the national law the matching conversation is the National Heavy Vehicle Accreditation Scheme, module by module. A profile that says only accredited has not said which module, or whether this driver is on standard hours or a more flexible arrangement. The limit on that driver's day is the constraint. A route planner's average speed is not that limit.
Australia's diesel is, in large part, imported refined product sold through coastal terminals. The Australian Institute of Petroleum publishes terminal gate prices for diesel on business days at the major gates. Buyers use that series as a wholesale price for a load collected at the terminal. On the AIP's own framing the figure includes excise and excludes GST. It excludes freight, any supplier differential, waiting and time on the customer's pad. It is a reference, not a delivered price. Western Australian lifts go through the Kwinana terminal precinct, an import gate rather than a refinery still running on that site. Perth and Kwinana supply starts its clock there. A regional delivery can be on the road overnight, so the day the product was loaded and the day it was dipped are different facts and should be stored as different facts.
That split matters as soon as a price formula uses the terminal gate price on the day of lift and a stock system uses the day of the dip. One timestamp cannot serve both. The board a fuel distributor works from is the terminal, the load window, the truck, the driver, the site window and the product. How a diesel supplier is organised between rack and customer is the operating shape underneath any screen. Where the supplier runs its own tankers, the roster and the site approval can sit in one business. Atlas Fuel's bulk and onsite diesel is run that way, on its own fleet out of Kwinana Beach, with Western Australian Heavy Vehicle Accreditation on the vehicles that need it. A brokered truck can still be the right overflow. The dispatch record should say which of the two is coming, because the induction and the maintenance system do not automatically follow the load.
Telemetry that raises an order on its own is useful only after those constraints sit in the same system. The order needs a tank identity, a product grade, a volume that fits the ullage, a site that is open, and a receiver who will be there. A mine gate that requires a day's notice does not care that the probe crossed a setpoint at 16:10. A farm track closed after rain does not care that the software prefers that day. A hold has to be visible, or the next person releases it just to clear the queue.
An arrival message says the truck is near. It does not say the hose is on the right tank. Sites with several tanks, or with diesel beside petrol, AdBlue or waste oil, still need a physical check before the docket can close. Record arrival and the start of discharge separately, because waiting time turns on that gap.
Diesel volume moves with temperature. Bulk trade in Australia corrects to 15 degrees Celsius. The proper factor depends on the density of that batch. For planning, a workable field figure is about 0.08 per cent per degree Celsius, an approximation rather than a laboratory result. A meter ticket of 30,000 litres observed at 35 degrees, twenty degrees above the reference, is expanded by about 1.6 per cent. That is about 480 litres. The 15-degree equivalent is near 29,520 litres. If the contract sells corrected volume and the invoice stores the raw ticket, the dispute is those litres.
Meters used to determine a quantity for sale sit under Australia's trade measurement system, administered by the National Measurement Institute. A meter that decides the invoice is expected to be suitable for trade and verified. Automatic temperature compensation uses a probe in the stream and prints a corrected volume when it is working. If the probe fails, the ticket may show a gross volume only, or a volume corrected with a default nobody noticed. The docket has to show the observed temperature and whether compensation was on. A corrected figure with no temperature, or a gross figure later described as corrected, cannot be checked.
The stock account is where mixed units do the real damage. Consider a tank whose opening stock is already stated at 15 degrees as 40,000 litres. A load arrives with that observed total of 30,000 litres at 35 degrees, about 480 litres above its corrected equivalent. Dispensers compensated to 15 degrees later issue 18,000 litres. The closing dip, taken when the tank is back at 15 degrees, reads 51,400 litres. Entered on one basis, the book is 40,000 plus 29,520 minus 18,000, which is 51,520. The dip is 120 litres lower.
Entered as many systems still do it, with the warm ticket beside corrected figures, the book is 40,000 plus 30,000 minus 18,000, which is 52,000. Against the same dip the site has lost 600 litres on paper. Most of that loss is the 480 litres of temperature. The units did not match. Pick one basis, convert every term, and store the conversion beside the raw reading. The meter measures what passed the hose. The dip and the chart measure what the tank should hold. Variance needs both, on the same temperature basis. Bulk diesel delivery still ends with those two numbers.
Electronic proof of delivery is useful only when the fields are the ones an argument needs. A signed screen with a single total, and no temperature, tank or meter identity, is still a weak record. The order, the delivery and the invoice have to match without a clerk reconstructing the week.
The commercial match is a three-way check: the order or call-off, the proof of delivery, and the supplier invoice. Litres, tank, date and price basis have to agree. Price basis means the terminal, the day of the lift, and whether the formula was a terminal gate price plus a differential or some other written arrangement. What a bulk drop costs once freight and waiting are added is a pricing question. The docket has to keep litres separate from a price movement, and keep the lift date when the dip is the next day. A tax invoice can still be valid while saying only diesel and a dollar figure. Quantity belongs on the delivery document.
Fuel tax credits, under the Fuel Tax Act 2006, refund embedded excise on taxable fuel acquired for eligible business use. Mining, agriculture, other off-road plant and heavy vehicles are where most commercial diesel claims sit, and the rate is not the same for each. Fuel used in a heavy vehicle on a public road is reduced by the road user charge. Eligible off-road use is claimed at a different rate. Both rates are published by the Australian Taxation Office and move when excise is indexed, in February and August. The notes here are the shape of the file, not tax advice.
A claim needs evidence of acquisition and evidence of use. The Tax Office expects those records to be kept for five years. Electronic dockets, dispenser logs and card statements qualify when they show quantity, date, supplier and a basis for splitting uses. Do not hard-code the credit rate in the gauge. Store the facts, and apply the Tax Office rate for that acquisition on the business activity statement.
Apportionment is where the record either helps or pretends to. The Tax Office accepts a fair and reasonable method if it is documented and kept. That is easier when each litre is tied to an asset and the asset to a use: a haul truck on the lease, a header in the paddock, a prime mover on the highway, a generator in a building. A communal bowser with no asset identity forces a percentage, and that percentage goes stale when the harvest or the public-road work changes.
A fuel card records litres the yard tank will never see. Light vehicles, one-off trips and trucks that do not domicile at the depot buy at retail fuel sites and at truck stops. The card profile can restrict product, volume, time of day, site and vehicle, and it can demand a PIN and an odometer. Those controls work when they are switched on and someone reads the exceptions. They do nothing when every card is open, the odometer is skipped, and the month arrives as one journal. Reject a reading lower than last time, or a jump the vehicle could not have driven.
Card litres and bulk litres are different stock. A card fill of a vehicle that also draws from the yard bowser, posted twice, or a bulk delivery dropped onto the same code as the card file, makes the fleet look as if it burned both. Reconcile each stream to its own documents, and add them only after that if a whole-of-fleet total is required. Bulk delivery and servo fuel also sit on different price bases, so averaging them hides which channel is expensive. Keep the streams identifiable.
Cards support a fuel tax credit file for the on-road vehicles they filled. They do not describe the mine tank, the header or the generator. AdBlue is not diesel and does not share a diesel hose, so the product lock belongs on the card and on the bulk order.
A terminal certificate describes the product at the rack. It does not describe the tank three weeks later. Water, time, temperature and a biodiesel component change what is in the shell. Fuel testing is the point at which an argument about dirty fuel becomes a result: appearance, density, flash point, water, particulate, and microbial activity where the symptoms fit diesel bug. The automotive diesel standard made under the Fuel Quality Standards Act caps sulfur at 10 mg/kg and sets a minimum flash point of 61.5 degrees Celsius. Those limits describe compliant product as supplied. They say nothing about a tank that has sat through a wet summer with a leaking hatch.
Sampling is the part software cannot invent. A retain at the hose, labelled with the docket number, and a bottom sample taken before the load is fully mixed, are what make a later result mean something. A dispenser sample a fortnight later answers a different question. Agree who samples, who pays, and what result changes the outcome before anyone is angry. A particulate cleanliness code, where a mine or an engine maker sets one, is a contract term, not a national fuel-quality limit. A filter change belongs in the same history as the certificate.
The order and the docket should name the diesel grades actually loaded. Mineral diesel and a biodiesel blend do not behave the same way in a tank that already holds water. Blend percentage belongs in the tank history, because microbial growth and filter blocking follow water and fatty acid methyl esters more readily than clean mineral diesel that turns over quickly. A planning tool that sees only litres will report a normal burn while the dispensers choke. Diesel quality checks from the storage side cover the same risk in more detail.
Compliant automotive diesel, with a flash point at or above the 61.5 degree minimum, sits above the 60 degree line used to classify Class 3 flammable liquids for transport under the Australian Dangerous Goods Code. In ordinary bulk supply it moves as a combustible liquid, not placarded as Class 3. That is a transport classification. It is not a claim that the product is harmless, or that the tank is unregulated. AS 1940, on storing and handling flammable and combustible liquids, places a liquid in that flash-point band in the combustible category, in the C1 range used across industry. Bunds, separation, ignition control and spill equipment still apply.
Licensing and manifest duties under state dangerous goods and work health and safety laws depend on quantity and class. The thresholds are not the same in every jurisdiction, and they are not zero because the truck carries no Class 3 placard. A diesel spill is still pollution. The dispatch profile should carry the classification as data. Petrol is Class 3. A diesel parcel that fails the flash-point minimum can fall back into Class 3 and must not travel on yesterday's assumption. Solvents, jet fuel and some heating products need their own entries. The grade on the order selects the placarding, the protective equipment and the site rule. A generic fuel flag is how the wrong rule arrives with the truck.
A level alarm is not a spill plan, and an electronic docket is not a safety data sheet. Overfill protection, bund capacity and a closed drain valve are still physical controls. Use the same tank identity for the reorder and for the site's emergency information, so a high alarm and a spill response are about the same vessel. Three shells that all answer to Tank 1, depending on the screen, are not ready for either job.
Once receipts, issues and dips share a temperature basis, a burn rate is usable. Until then a forecast charts the errors. Days of cover travels well between sites: usable litres divided by expected daily draw. A reorder point in litres hides whether the site has four days or four hours. Lead time includes the rack, the road, the fatigue break and the site window, not only the hours a map quotes. Buffer stock is that lead-time demand, plus the variation the site has actually seen, plus the day the gate or the weather will take.
Seasonal profiles beat a flat average. Seeding and harvest, the northern wet, cyclone cuts, mine shutdowns and restarts, fishing seasons and generator tests all move the draw. Treat a software suggestion as a draft. The person who can see next week's production plan has to be able to edit next week's fuel plan, with the edit left visible.
A terminal gate price can jump while the site burns a steady litre, and the invoice total will jump with it. A tool that infers consumption from dollars will call that a demand spike and may order product the tank cannot take. Store litres and dollars apart, and store the terminal and the price day against the load. Rack congestion, a terminal short of a grade, or a lift pulled forward ahead of an indexation date are supply events. They are not evidence that the site used more fuel.
A mine fuel farm is several tanks, a cleanliness expectation, a gate, and plant that does not drive to a servo. Telemetry has to resolve tank by tank, because a healthy total can hide one empty shell. On mining fuel sites, dispatch has to carry induction expiry, the approved combination and the window the pit will actually accept. Drawdown before maintenance, and the surge on restart, both have to change the reorder logic. The physical delivery is covered in the notes on mine-site diesel delivery. Technology adds a shared tank identity and an open-order view. It does not soften the gate.
A farm tank is often one shell, one bowser and one person who is also in the seeding or the harvest. Coverage is patchy, the burn is violent for a short season, and the same tank may feed a header, a truck to the bin, and a ute. Those uses are not the same for fuel tax credits or for ordering. Farm diesel supply fails when a July reorder point meets a harvest week, or when the only alarm goes to a phone left in the ute. Use a seasonal profile, a named person, and a buffer that covers the longest gap between a call and a truck. Farm delivery during those peaks is still a tanker problem. The probe's job is to make the call early enough that the tanker can arrive inside the driver's hours.
Industrial yards sit between those extremes: a bulk tank, a bowser, contractors who should not share one untagged nozzle, and sometimes a generator day tank on a transfer pump. Fleet depots add the card file for vehicles that never come home. Yard issues and card issues have to stay separate in the reconciliation. Marine fuel measurement is the same temperature problem in a tighter window. Barge or bunkering meters, product temperature and the vessel's soundings have to be written down as a set. One delivered figure with no temperature starts the same argument as a warm ticket in a cold stock account, with less time to resolve it. Across these sites the pattern holds: identity of the tank or vessel, identity of the product, volume on one temperature basis, and a person who may order.
No sensor takes the sample, connects the hose, or signs for a variance. No route plan holds a fatigue accreditation the driver does not have. Other fuels and newer engines matter in some fleets, and they do not empty a remote tank or a header this season.
Physical delivery is still a tanker business. Atlas Fuel states ISO 9001, ISO 14001 and ISO 45001 for its management systems, and runs its own tanker fleet for bulk and onsite diesel from Kwinana Beach. Sites that want that physical supply lined up with the way they already watch their tanks can contact the business and talk through the tanks, the windows and the records, rather than a promise that the truck has been automated away.
No. A day tank is small, fed by a transfer pump from the bulk shell, and it often supplies a load the site cannot drop. The bulk gauge can look comfortable while the transfer has failed. Give the day tank its own high and low points. Tag planned generator tests as known issues so a test burn does not look like theft or a demand spike. Post the transfer as a movement between tanks, not as consumption, or the bulk account shows a use that has not yet reached an engine.
Hold the story until the dispenser totals, any internal transfer log, and a manual dip are on the table. The drop may be theft, a leak, an unmetered contractor draw, a transfer into a day tank, or a probe that has jumped. An automatic reorder that replaces the missing litres will hide a leak, and it may overfill the tank if the gauge was the failure. If the dip confirms a real loss and the dispensers do not, treat it as an incident first. Put that incident in the same tank history as the deliveries.
The delivery happened, or it did not, and the file has to say which. Store the time, the names present, the reason the signature was refused, a photograph of the meter, and any dip taken before the truck left. If product was discharged, name the tank. If it was not, the order is still open and must not show as a completed job with a blank signature. Agree in advance which variances are large enough to refuse a signature, so a driver is not held over a gap both sides already know is temperature.
Treat the change of grade as its own event. If the tank still holds a heel of the previous product, the next sample and the next filter inspection belong to the mixture, not only to the certificate on the new load. Pause any automatic reorder that assumes a single grade until the site has accepted the blend now on the order. Litres can stay in the burn forecast. The quality watch starts again from the load that changed what is in the shell.
They can, if every draw is tagged to an entity and a use before the nozzle goes back. An untagged communal bowser cannot be split later by guessing whose plant was on site. The commercial agreement and the tax record need the same tag: which company acquired the litre, and whether the use was off-road plant or a heavy vehicle on a public road. A monthly percentage is only as good as the note that explains it, and it has to be revised when the mix of machines changes. Eligibility itself stays with the Tax Office rules and the claimant's own advice. This is the shape of the record, not a ruling on a particular use.
Rebuild it when the shell has changed, not when the software has. A new floor, a repair, a tank that has been moved, or settlement that has tilted a horizontal vessel all change the relationship between height and litres. A verified meter on the truck does not replace the chart: the meter measures the hose, and the chart measures the vessel. After structural work, re-strap the tank and load the new chart into every system that converts level to volume, including a supplier portal that reorders from your figure.
Hold or cancel automatic replenishment before the drawdown. Do not let a low alarm refill a tank the site is trying to empty for work on the shell or the bund. Rebuild cover against the restart plan, which is often a surge rather than a return to the old average. A model trained on steady weeks will send a tanker to a closed gate or leave the restart short. Put the shutdown on the tank as a status anyone can see before they release an order. When the status lifts, the first load is a human decision checked against ullage and the restart fleet, not a backlog of alerts firing together.